Ara
Toplam kayıt 2, listelenen: 1-2
Effect of the Stator Slot Indents on Fluid Damping Loss in Submersible Pump Applications
(IEEE, 2022)
In this study, the effect of fluid damping on the performance of a 2-pole, 4-kW line start synchronous reluctance machine (LS-SynRM) with different slot opening structures for submersible water pump applications is ...
Investigating the Role of Stator Slot Indents in Minimizing Flooded Motor Fluid Damping Loss
(MDPI, 2023)
This research examines how fluid damping loss affects the operation of a two-pole, 5.5 HP
(4 kW) induction machine (IM) within the context of different slot opening configurations developed