dc.description.abstractConventional 2-pole AC machine windings have long end windings and generate harmonics, which increase losses and reduce torque density. This study investigates the performance tradeoff between the level of distortion (THD) in winding magneto-motive force (MMF) and end turn length on a 2-pole line start Synchronous Reluctance Machine (LS-SynRM) machine. A two-stage approach is used, winding and geometry optimization. Various multilayer winding configurations having unevenly distributed number of turns are investigated. First, the percentage of the turns in a coil group is optimized for minimum harmonics and end turn length for all structures. Second, geometric optimization is performed on selected winding configurations. Sixteen different configurations are optimized, and Pareto optimal solutions are obtained. Later, these solutions are graded with a new score-based assessment method to quantify the quality of the results. It is concluded that the designs having lower THD in winding MMF perform better than the designs with shorter end turns in terms of efficiency and torque density.en_US
dc.description.sponsorshipThis work was funded by The Scientific and Technological Research Council of Turkey (TUBITAK) under Grant number 121E413.en_US
dc.language.isoengen_US
dc.publisherInstitute for Ionicsen_US
dc.relation.isversionof10.1007/s40998-023-00643-4en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectWinding MMF harmonicsen_US
dc.subjectMulti-objective optimizationen_US
dc.subjectDifferential evolutionen_US
dc.subjectEnd winding optimizationen_US
dc.subjectReluctance machineen_US
dc.titleInvestigating the Tradeoff Between the MMF Distortion and End Turn Length of a 2-Pole Line Start SynRM Performanceen_US
dc.typearticleen_US
dc.contributor.departmentAGÜ, Mühendislik Fakültesi, Elektrik - Elektronik Mühendisliği Bölümüen_US
dc.contributor.authorID0000-0003-2720-8816en_US
dc.contributor.authorID0000-0001-7995-0540en_US
dc.contributor.institutionauthorTekgun, Didem
dc.contributor.institutionauthorCosdu, Muhammed Muhsin
dc.contributor.institutionauthorTekgun, Burak
dc.contributor.institutionauthorAlan, Irfan
dc.identifier.volume47en_US
dc.identifier.issue4en_US
dc.identifier.startpage1447en_US
dc.identifier.endpage1457en_US
dc.relation.journalIranian Journal of Science and Technology, Transactions of Electrical Engineeringen_US
dc.relation.tubitak121E413
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster